Lillen comes equipped with an electric bed.
The bed is operated from the control switch that is located under the TV unit.
Before lowering the bed, remove all cushions and lower the table to it’s lowest setting.
Pressing and holding the switch in the UP position moves the bed upward.
Pressing and holding the switch in the DOWN position, moves the bed downward.
Example video of how the bed comes down from the ceiling.
The manufacturers operating manual is available as a PDF download.
In the unfortunate event that the bed has stopped working please follow the below steps.
First check that button 1 and 2 on the Battery and Water Control Panel are turned on.
If the cables are properly connected, the next place to check is the fuse box that is located under the passenger couch behind the driver seat.
The bed’s 20A fuse is located inside the fuse box next to the blue Electroblock.
Remove the fuse box plastic the cover.
Check the first 20A fuse fromt the right.
Example of what a demaged fuse looks like.
There is a Spare Fuse Kit inside the storage hatch at the rear on the right side (where the water hoses are stored).
If the bed will not raise when using 12V, check the power level of the “house battery” on the Battery and Water Control Panel.
If the battery level is between 11.0 and 12.2 e.g red and amber lights there might not be enough voltage to lift the bed back up.
Example of low power,
If this happens follow these steps,
Check that the electrical cables that hang down on the inside of the storage hatch on the left rear side are properly connected.
Remove the metal cover using a phillips screwdriver.
Ensure that all cables are properly secured.
According to the electric bed manual, there is an option for manual operation of the bed. It is a two-man job and it seem to be a complicated procedure.